Model C tank Specs and Drawings

Specifications and Drawings

Download Specification Table (PDF)

Download CALMAC App from your Apple or Android device.

Download CAD files by clicking on the links below.

TANK MODELS

1082C

1098C

1105C

1190C

1320C

1500C

View PDF Drawings 1082C2F
1082C3F
1082C4F,
U4F
1098C2F
1098C3F
1098C4F
1105C2F
1105C3F
1105C4F,
U4F
1190C2F
1190C3F
1190C4F

1320CSF

1320CRF

1320C4F

1500CSF

1500CRF

Download CAD drawings: 1082C2F
1082C3F
1082C4F
1082CU4F

1098C2F

1098C3F

1098C4F

1105C2F
1105C3F
1105C4F
1105CU4F

1190C2F

1190C3F

1190C4F

1320CSF

1320CRF

1320C4F

1500CSF

1500CRF

Net-Usable Capacity Ton-Hrs. (kWh (i) 82
(288)
98
(345)
105
(369)
162
(570)
324
(1140)
486
(1710)
Max. Operating Temp., ºF (ºC) 100
(38)
100
(38)
100
(38)
100
(38)
100
(38)
100
(38)
Factory Tested Pres., psi (kPa) 250
(1724)
250
(1724)
250
(1724)
250
(1724)
250
(1724)
250
(1724)
Max. Operating Pres., psi (kPa) (ii) 90
(620)
90
(620)
90
(620)
90
(620)
90
(620)
90
(620)
Dimensions (ODxH), in. -- -- -- -- -- --
Dimensions (WxLxH), in. (mm) (iii)

(2F)

73¾ x 75 x 84½
(1875 x 1900 x 2140)

(3F, 4F, U4F)
73¾ x76½ x 84½
(1875 x 1940 x 2140)

(2F)

89 x 91x 69½
(2260 x 2310 x 1765)

(3F,4F)
89 x 92 x 69½
(2260 x 2340 x 1765)

(2F)

73¾ x 75 x 101
(1875 x 1900 x 2590)

(3F, 4F, U4F)
73¾ x 76½ x 102

(1875 x 1940 x 2590)

(2F)

89 x 91x 102
(2260 x 2310 x 2590)

(3F, 4F)

89 x 92 x 102

(2260 x 2340 x 2590)

(SF)
89 x 180 x 102
(2260 x 4580 x 2590)

(RF)

89 x 182 x 102

(2260 x 4620 x 2590)

(SF)
89 x 270 x 102
(2260 x 6860 x 2590)

(RF)

89 x 272 x102

(2260 x 6910 x 2590)

Shipping Weight, lb (kg (iv) 1065
(485)
1275
(580)
1315
(595)
2000
(910)
4000 
(1815)
6000 
(2720)
Weight, Filled, lb (kg) 8580
(3890)
10,235
(4645)
10,885
(4935)
16,900
(7665)
34,000
(15,420)
50,600
(22,950)
Floor Loading, lb/sq.ft., (kg/m ²) 286
(1396)
237
(1157)
363
(1772)
391
(1909)
391
(1909)
391
(1909)
Volume Of Water/Ice Gal (l) 820
(3105)
980
(3710)
1045
(3955)
1655
(6265)
3310
(12,530)
4965
(18,795)
Vol. Solution in HX, Gal (l) 86
(326)
90
(341)
99
(375)
157
(594)
315
(1192)
472
(1787)
Inlet/Outlet Flange Connections. in. 4 4 4 4 4 4

Total burial option. Download drawing:
Full Burial Models 1190XC (2F, 3F, 4F); 1320XC & 1500XC (RF & SF)

i. Typical value, actual varies with conditions

ii. Consult factory for higher ratings

iii. Tolerance for all dimensions is + 1/2" except "L" for Models 1500 and 1320 where + 1".

iv. Shipping weight may vary slightly because of differences in volumes of residual water from hydrostatic test

Partial burial option. Download drawing:

Partial burial example